Light levels by space

Space Footcandles Lux Notes
Living room 10–20 110–220 Ambient; add lamps for reading
Dining room 10–20 110–220 About 10 on the table for everyday dining, 20 for homework or work
Kitchen, general 30–40 320–430 Counters and sink 50 or more, usually from task lighting
Bedroom 10–20 110–220 About 30 for reading in bed
Bathroom 20–50 220–540 About 20 vertical at the face at a vanity
Home office 20–50 220–540 30 for screen work and normal print
Hallway or entry 5–20 50–220
Open office 30–40 320–430 30 for screen work in IES task tables
Conference room 30 320 30 on faces for video calls
Restaurant, casual 10 110 Fast food about 20
Restaurant, fine dining 3 30 Low ambient with focused light on tables
Café or coffee shop 10 110
Hotel lobby 10 by day, 5 at night 110 / 50 Reception desk about 40
Retail 20–40 220–430 Furniture stores about 20; accent displays 3–10 times ambient

Commercial values follow the IES Lighting Handbook, 10th edition, as compiled by utility lighting programs. Residential ranges come from IES-based guidance (Penn State) and reported values from ANSI/IES RP-11. Newer IES recommended practices may differ. IES targets assume most occupants are 25–65: double them where most are over 65, and halve them where most are under 25. One footcandle is one lumen per square foot, about 10.8 lux.

From light levels to lumens

Multiply the floor area by the target footcandles to get the lumens that need to reach the work surface: a 12 × 14 ft dining room at 10–20 fc needs 1,680–3,360 lumens there. A common rule of thumb is that about half of a fixture’s lumens arrive, after losses to walls, ceiling, shades and ageing, so plan to install about twice that; the real share depends on the fixture and the room. Dark finishes, tall ceilings and deep shades need more. Our lighting calculator does this for you and counts fixtures.

Colour temperature

Colour temperature Looks like Typical uses
2200–2700 K Warm, candle to incandescent Restaurants, bars and lounges; dimmed evening light
2700–3000 K Warm white Living rooms, bedrooms, dining and hospitality
3500–4100 K Neutral white Kitchens, offices, retail and work areas
5000–6500 K Cool, bluish daylight Task lamps, garages and spaces that need colour checking

Ranges after ENERGY STAR; typical uses after Energy Trust of Oregon, which suggests about 2700 K for living rooms, 3500 K for kitchens and 5000 K for reading lamps. California’s Title 24 limits high-efficacy residential light sources to 4000 K or less.

Colour rendering

  • CRI 80 is the usual minimum for general lighting.
  • CRI 90 or more, with an R9 (saturated red) value of 50 or more, is the premium tier, and what California’s Title 24 (Joint Appendix 8) requires of high-efficacy residential sources. Use it wherever wood, fabric, food or skin tones matter.
  • CRI predicts preference only loosely. The newer TM-30 metrics (fidelity Rf and gamut Rg) describe colour quality more fully.

Sizing decorative fixtures

Rule of thumb How to use it
Chandelier for a room Room length + width in feet = diameter in inches. A 12 × 14 ft room takes about a 26" (66 cm) fixture.
Chandelier over a table One-half to two-thirds of the table width, and at least 12" (30 cm) narrower than the table.
Height over a table 30–36" (76–91 cm) from tabletop to the bottom of the fixture under an 8 ft ceiling; add about 3" (8 cm) for each extra foot of ceiling.
Pendants over an island or table 30–36" (76–91 cm) above the surface, about 24–30" (61–76 cm) apart centre to centre for small shades. One pendant up to about 4 ft of length, two to about 7 ft, three beyond, adding one for about every 3 ft past 10 ft. Keep the outer pendants 12–20" (30–51 cm) in from the ends.
Fixtures over walkways Designers keep the bottom of a fixture at about 7 ft (213 cm). The ADA requires at least 80" (2,030 mm) of headroom on circulation paths, and the BC Building Code 2,050 mm (81") in exits and access to exits.

Fixture rules come from lighting manufacturers and retailers; no standards body publishes them, so treat them as starting points and check the scale on site.

×